top of page

SNA5000A

Vector Network Analyzer

Frequency Range

Up to 8.5GHz

Dynamic Range

125dB

Output Level

-55dBm ~ +10dBm

Level Resolution

0.05 dB

Analyze the signal, characterize the network! 

The SIGLENT SNA5000A series of vector network analyzers has a frequency range of 9 kHz to 8.5 GHz, which supports 2/4-port scattering, differential, and time-domain parameter measurements. The SNA5000A series is ideal for determining the Q-factor, bandwidth, and insertion loss of a filter. It features impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear-Frequency mode, Log-Frequency mode, PowerSweep mode, CW-Time mode, and Segment-Sweep mode. They also support scattering parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.

Main Features

  • Frequency range: 9 kHz ~ 8.5 GHz

  • Setting range of output level: -55 dBm ~ +10 dBm 

  • Dynamic range: 125 dB 

  • Support 2/4-ports scattering-parameter, differential-parameter, and time-domain parameter measurements

  • Support one-key measurement of  Q-factor, bandwidth and insertion loss of a filter

  • Support  impedance conversion, fixture simulation and adapter removal/insertion adjustments

  • Optional spectrum analyzer and TDR functions

Download Here

Specifications

Frequency Range

4.5GHz/8.5GHz

Support Bias-Tees

Yes

Frequency Resolution

1Hz

Interface

LAN, USB Device, USB Host(USB-GPIB)

Level Resolution

0.05dB

Remote Control

SCPI / Labview / IVI based on USB-TMC / VXI-11/ Socket / Telnet / Webserver

Range of IFBW

10Hz ~ 3MHz

Touch Control

Multi Touch, Mouse, Keyboard

Setting Range of Output Level

-55dBm ~ +10dBm

Screen

12.1-inch touch screen

Dynamic Range

125dB 

Video Output

HDMI

Types of Calibration

Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port calibration, TRL calibration

Types of Measurement

Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion

Model
Frequency range
Ports
Dynamic range
Trace noise
Range of output level
SNA5014A
9kHz ~ 8.5GHz
4
125dB
0.003dB rms,0.03°rms
-55 dBm ~ +10 dBm
SNA5012A
9kHz ~ 8.5GHz
2
125dB
0.003dB rms,0.03°rms
-55 dBm ~ +10 dBm
SNA5004A
9kHz ~ 4.5GHz
4
125dB
0.003dB rms,0.03°rms
-55 dBm ~ +10 dBm
SNA5002A
9kHz ~ 4.5GHz
2
125dB
0.003dB rms,0.03°rms
-55 dBm ~ +10 dBm
bottom of page